Shallow talk about maintenance intelligent toilet fault tips

by:ANNWA SANITARYWARE     2020-08-08
Intelligent toilet facilities are essential to life, for a long time use, hard to avoid can appear some problems of maintenance, me say intelligent implement maintenance common problem: 1, the toilet jams: flush enough or into foreign body or aging will cause the toilet jam, there are many ways to dredge the toilet and touch soft content block, using a simple dredge tools generally can be solved. Hard plug typically take apart the toilet dredge. 2, leaky toilet, toilet cistern fittings, aging or damage failure usually float or water sealed cover is easy to be a problem. It is ok to change. 3, toilet installation problem: when installed at the bottom of the use glass glue or cement, don't block the toilet when installed at the bottom of the screw holes. 4, closestool buttons: the most common is the double button, button failure it is ok to change directly. 4. Intelligent implement fault phenomenon: the water is not hot check part intelligent implement fault handling way: remote control temperature set at room temperature? The wait for 10 minutes, no hot, please remove the measuring tank resistance is about 92 ohms around on both ends of the hotline, and test whether there are about 92 ohm resistor on both ends of the heating tube, without the fuse bad, measuring temperature sensor at the ends of the resistance is normal, if all the bad computer board, such as in the tank, change detection is normal, after water have been heating is computer board bad to change together. 5. Intelligent implement fault phenomenon: temperature intelligent heating check part to implement fault handling way: set the state without heating, heating with the remote control, please remove the seat plus hotline measurement on both ends of about 960 + / - 50 ohm resistance value, without heating wire open, if there are any measurement value as normal on both ends of the temperature sensor, connector contact is good? If normal computer board. After such as change seat, change detection is normal, such as seat have been heating is computer board bad to change together. 6. Intelligent implement fault phenomenon: the blast temperature is not hot check parts: intelligent implement fault handling way: measuring drying on both ends of the heating wire frame to see if there is 89 + / - 4 ohm resistance without the drying device is bad, if yes, confirm the correct seat press drying after measuring the heating wire is there a 220 v voltage on both ends of the box outlet, such as no voltage is bad computer board. Such as in drying devices should be careful inspection computer board. Remark: if short circuit between motor groove back sometimes caused by the increasing load and speed slow heating wire box open, can also lead to computer board D882 burning phenomenon occurs, then please tell the computer board and drying device at the same time. Intelligent implement common troubleshooting way no wonder the above several, if not processing, can ask professional personage to processing.
Custom message
暂无友情链接数据
Chat Online 编辑模式下无法使用
Chat Online inputting...